# hr50ctl
|
|
|
|
A small python tool that can be used to query information from the Hardrock-50 amateur radio power amplifier as well as sending commands and therefore to modify settings
|
|
|
|
## Features
|
|
|
|
Queries the followingy data from the Hardrock-50:
|
|
* Status (RX/TX)
|
|
* Keying method
|
|
* Band
|
|
* Voltage
|
|
* Peak power of last transmission
|
|
* Average power of last transmission
|
|
* SWR
|
|
* Temperature
|
|
|
|
Example:
|
|
|
|
```
|
|
+---------+----------+----------+------------+
|
|
| STA: RX | PTT: COR | BND: 20M | VLT: 13.8V |
|
|
| PEP: 58 | AVG: 58 | SWR: 1.2 | TMP: 20C |
|
|
+---------+----------+----------+------------+
|
|
```
|
|
|
|
Enables the user to alter the following parameters of the Hardrock-50:
|
|
|
|
* Keying method (OFF, COR, PTT, QRP)
|
|
* Band
|
|
* Initiate tuning process during next transmission
|
|
|
|
## Install
|
|
|
|
hr50ctl needs Python 3 and the following libraries:
|
|
|
|
* prettytable
|
|
* pyserial
|
|
|
|
Perform the following steps to get hr50ctl up and running:
|
|
|
|
* Connect a Raspberry Pi to the Hardrock-50 with a USB cable (USB A to USB B)
|
|
* Download and extract the hr50ctl.py script
|
|
* Install the above mentioned dependencies with python3-pip
|
|
* Configure the following variables inside the Python script:
|
|
* serial_port: e.g. /dev/ttyUSB0
|
|
* baud: e.g. 19200 (must match with the settings made in your Hardrock-50)
|
|
* execute the script with
|
|
* python3 ./hr50ctl.py
|
|
|
|
## Usage
|
|
|
|
```
|
|
USAGE: # ./hr50ctl.py -b <band> -t -k <keying mode>
|
|
|
|
PARAMETERS:
|
|
-k: the following keying methods are available:
|
|
off, cor, ptt, qrp
|
|
This parameter changes the method how the HR50 will be put into TX mode.
|
|
-b: the following bands are available:
|
|
6, 10, 12, 15, 20, 17, 20, 30, 40, 60, 80, 160
|
|
This parameter changes the band of the HR50
|
|
-t: no parameter required.
|
|
This parameters initiates the tuning during the next PTT
|
|
|
|
EXAMPLES:
|
|
Change the band to 12m: # ./hr50ctl.py -b 12
|
|
Change the keying method to PTT: # ./hr50ctl.py -k ptt
|
|
Change the band to 6m and tune: # ./hr50ctl.py -b 6 -t
|
|
```
|
|
|
|
## Screenshots
|
|
|
|
![Screenshot](/hr50ctl.jpg)
|