Peter Wemm def9ab7a1f Deal with "cc -version" reporting "2.7.2.1" or any other junk that might
end up appended (eg: "2.7.2p" or the like).

Reported by: jhs@freebsd.org (who also suggested a different, larger patch)
1996-10-14 02:36:40 +00:00
..
patch-ab
patch-ad
patch-ae Deal with "cc -version" reporting "2.7.2.1" or any other junk that might 1996-10-14 02:36:40 +00:00
README

	NOTES ON HYLAFAX IN FREEBSD (/usr/ports/comms/hylafax)
		By Julian Stacey <jhs@freebsd.org> May 1995
		 
This port replaces flexfax (which is over a year old).
Thanks to Sam Leffler of SGI for writing & releasing Hylafax :-)
I <jhs@freebsd.org> wrote the FreeBSD ports/comm/hylafax/* files,

Copyright Julian Stacey 1995:
	Please preserve & comply with Sam Leffler's & SGI's legal stuff
	I hereby release my work in this area for public use, & disclaim
	all liability !  
	Leave my name intact please, I'm a freelance, publicity can be useful.

Documentation:
	- On Line Manuals: 	man hylafax.
	- World Wide Web site:	(http://www.vix.com/flexfax/
	- Source tree:		Local copies of web in html & html/FAQ etc.

Mailing List for Support, Development etc:
	Don't mail me your fax or modem problems, nor post Hylafax
	software bugs & fax modem problems to a Freebsd mail list.
	The correct mail list:		flexfax@sgi.com

Patches:
	Bug reports, accompanied by diff -c patches, will be reviewed &
	commited to FreeBSD/ports).

Examples:
	Syntax etc examples are in:  config.jhs config.ttyd1.jhs etc.ttys.jhs

My Test Environment:
	SupraFax V32bis + FreeBSD-2-current (May 1995)

Outstanding:
	I'm not sure if the lock file scheme is OK 
		(It may be, I just used the default).
	Some of the permissions are not right, 
		(sometimes I get many email acknowledgements for each fax
		sent (but fax is only sent once, no horrendous phone bill
		... yet ;-)
	My faxgetty will not answer as a normal modem (maybe its the modem,
	or maybe my config file is wrong).

---
Julian Stacey  <jhs@freebsd.org>  Tel. +49 89 268616.   Fax Modem: 2608126 
		http://www.regent.e-technik.tu-muenchen.de/people/jhs.html
Vector Systems Ltd: an Internet, Unix & C consultancy in Munich Germany

Appended are some example Config files:

etc.ttys
{-------
ttyd1 "/usr/local/sbin/faxgetty" vt100 on unsecure
-------}

config
{-------
LogFacility:		daemon
CountryCode:		49
AreaCode:		89
LongDistancePrefix:	0
InternationalPrefix:	00
DialStringRules:	etc/dialrules.europe
ServerTracing:		1
MaxSendPages:		20
-------}

config.ttyd1
{-------
# /var/spool/fax/etc/config.ttyd1 by jhs@freebsd.org
# from $Header: /usr/people/sam/fax/config/RCS/rockwell,v 1.25 1995/03/10 23:36:02 sam Exp $
# this file documented in man config

# Sam says:
# {
# If you stop faxq then faxd.recv will remove the job itself;
# otherwise if it sees faxq is running it passes the remove request on and
# assumes the task was completed (there is no acknowledgement).

# ServerTracing so that tracing messages are not sent out (listed in the
# TODO file, a fix is welcome).  If you think this might be happening, try
# echo "CServerTracing: 0x201">/var/spool/fax/FIFO
# to force faxq to reset the current value for ServerTracing.
# }

# Configuration for a Rockwell-based Class 2 modem.
#    Boca M1440E		firmware V1.270 or newer
#    Dallas Fax			(throw it away!)
#    Hayes Optima 24+Fax96	firmware TR00-J260-001 XXX or newer
#    SupraFAX v.32bis		firmware V1.200-C or newer
#    Twincom 144/DF		firmware revision V1.200 or newer
#    Dynalink 1414VE
# (and others)

# This configuration file sets up the modem to run at 19.2 for
# sending and for receiving.  XON/XOFF flow control is used on
# the tty port.  RTS/CTS can be used by switching the flow control
# setup, but beware of modems that do not support it during
# facsimile operations.  Also beware that the adaptive-answer
# facility, when supported, is usually unreliable.

# AdaptiveAnswer	boolean  No   enable adaptive answer of inbound calls
AdaptiveAnswer		Yes
# AnswerRotary		string	Any	alternatives for answering calls
# AnswerRotary		"fax data"
# DestControls		jhs set later see man destctrls

MaxDials		3 # max calls to transmit a job (presumably doing succesive pages)
# Wrong numbers cost me 23pf per fail, & earache to whoever answers the phone !
# MaxTries		3 # max attempts to transmit a job (3 default)
NoCarrierRetrys		0 # default 1 # number of times to retry dialing on ``NO CARRIER''

# JobReqBusy		integer	300	requeue interval for BUSY dial result

MaxSendPages		20 # max pages to permit in a send

# jhs later		QualifyTSI   file of TSI patterns for qualifying senders
CountryCode:		49
AreaCode:		89
FAXNumber:		+49.89.2608126	# also used to name session log file
LocalIdentifier:	"+49 89 2608126"
LongDistancePrefix:	0
InternationalPrefix:	00
DialStringRules:	etc/dialrules.europe
ServerTracing:		1
SessionTracing:		11
RecvFileMode:		0644 # if you have nosey users, consider 0600
LogFileMode:	0644	# make it 0600 if calling card access codes are logged
DeviceMode:		0600
RingsBeforeAnswer:	2
SpeakerVolume:		medium

# Any appearance of ``%l'' is replaced with the tty name and any
# appearance of ``%s'' is replaced with the serial port speed (in decimal).
GettyArgs:	"std.%s -" # "std.%s ttyd1" # default is "-h %l dx_%s"
# FreeBSD man getty says: 	getty [type [tty]]
# FreeBSD man login says: -h specifies host from which the connection received.
# kew@timesink.spk.wa.us (FreeBSD 2.1.0) uses "std.%s -".

TagLineFont:		etc/lutRS18.pcf
# pre jhs default was TagLineFormat:		"From %%l|%c|Page %%p of %%t"
# %c gives American-only date format, which is confusing in Britain or Germany
# so I use international accountancy date format: (19)95 08 01 (ie 1st Aug)
# I use no words in my tag line, as fax may be in German or English.
#---
# allow at least 4 spaces before VSL as PCS fax chops left margin
# dont actually use space char, as entabbing this file will lose it all
# dont put too much in any one field or will overprint
# %%l takes LocalIdentifier
# %%n sender fax ie +49.89.2608126
# %%d target fax ie +498968004525, from sendfax -d gary@68004.525
# %%p page number inc. cover sheet
# %%t total pages inc. cover sheet
# jhs created `pages' symbol (\241 dec161 xa1) in lutRS18.pcf
# jhs created `phone' symbol (\244 dec164 xa4) in lutRS18.pcf
# `phone' & `pages' are inspired by symbols that pcs fax machine prints
# PCS FAX is "Canon Fax 280" Model H11232, + H11 2325 + HA2 1324, REN=3
TagLineFormat: "Fax %%n|Tel \244 +49 89 268616|\241 %%p/%%t %Y:%m:%d %H:%M"

# MaxRecvPages:		unlimited

# Modem-related stuff: should reflect modem command interface
# and hardware connection/cabling (e.g. flow control).

ModemType:		Class2		# use class 2 interface
ModemRate:		19200		# fax send&recv is locked at 19.2
ModemFlowControl:	xonxoff		# default

ModemResetCmds:		AT&F2		# what you want for a Supra # JJ I have not checked operation since enabling this
ModemNoFlowCmd:		AT&K		# disable flow control cmd
ModemHardFlowCmd:	AT&K3		# hardware flow control cmd
ModemSoftFlowCmd:	AT&K4		# software flow control cmd
ModemSetupDTRCmd:	AT&D3		# DTR off causes modem to reset
#ModemSetupDTRCmd:	AT&D2S25=1S38=0	# Dynalink 1414VE needs this
ModemSetupDCDCmd:	AT&C1		# DCD follows carrier
ModemSetupAACmd:	AT+FAA=1+FCLASS=0 # enable in current class
# FAQ says: AT+FAA=1	Auto answer as facsimile or data depending on call

ModemSendFillOrder:	LSB2MSB		# as expected
ModemRecvFillOrder:	MSB2LSB		# opposite of what makes sense

ModemDialCmd:		ATDT%s@		# T for tone dialing, @ for silence

# Caller ID configuration setup for Supra.

# QualifyCID:		etc/cid	(off by default) CID access control list file
CIDNumber:		"NMBR = "	# pattern string for phone number info # JJ I have not checked operation since enabling this
CIDName:		"NAME = "	# pattern string for identity info # JJ I have not checked operation since enabling this

# DEFAULTS FOR REFERENCE
# ModemAnswerFaxCmd             string     ATA              command for answering fax call
# ModemAnswerDataCmd            string     ATA              command for answering data call

# Class1RecvIdentTimer
#               The time, in milliseconds, to wait for  an  initial
#               DCS  when receiving a facsimile.  CCITT recommenda-
#               tion T.30 specifies this as the  value  of  the  T1
#               timer.  However, adaptive answering schemes such as
#               that  described  above  under  the   AdaptiveAnswer
#               parameter may require that this timer be shortened.
# Class1RecvIdentTimer  35000 Class 1: max wait (ms) for initial ident frame
Class1RecvIdentTimer	12000

# Supra default wait for carrier is 50/10th sec, change with ats7=255
# Datatronic default wait for carrier is 45/10th sec.
# matthias says:	config.ttyd1
# 
# FaxT1Timer
#	should  not be changed without full understanding of the ... server.
#               The value of the T1 timer  in  milliseconds.   This
#               timer  is used to time out the initial session con-
#               tact; i.e. receipt of DIS/DCS.
# FaxT1Timer             35000            CCITT T.30 T1 timer (ms)
# 
# AdaptiveAnswer:
# Class1RecvIdentTimer  should be set to a value that
#               is shorter than FaxT1Timer.
# yet defaults for both are exactly the same: 35000 / 1000 sec.

UUCPLockDir	/var/spool/lock	# jhs added this after seeing where kermit created a lock.
UUCPLockType	ascii	# jhs added this after seeing what kermit created
# Note kermit -l /dev/supra created /var/spool/lock/LCK..supra
# (supra is a link to cua01, so the lock wont really work, as I'm running
# gettyfax on ttyd1.
-------}