The numbering of document.dump.color_mode and terminal._template_.colors
is now the same regardless of compile-time options, unlike in previous
versions. Therefore this version of ELinks may interpret a configuration
file differently from previous versions even if compiled with the same
options. This is unfortunate but the alternatives (keeping the numbering
dependent on configuration options; defining separate options that use
the new numbering; starting the numbers from 10 or so and recognizing the
previous ones only for compatibility) seem even worse.
This does not conflict with querying the palette from xterm (bug 890)
because although those palettes would have to be modifiable, they
would be terminal-specific rather than global.
UCS_ORPHAN_CELL is currently defined as U+0020 SPACE, which was
already used before this macro, so the behaviour does not change,
but the code seems clearer now.
I searched for ' ' and 32 and 0x20 and \x20, and replaced with
UCS_ORPHAN_CELL wherever UCS_NO_CHAR was involved. However,
some BFU widgets first draw spaces and then overwrite with text;
those will require a more complex fix if UCS_ORPHAN_CELL is ever
changed to some other character.
The previous version assumed the first non-digit after the CSI was the
Final Byte, for example the first semicolon in the "\E[?1;2c" report.
It then treated all subsequent bytes as typed characters.
According to Standard ECMA-48 (Fifth Edition - June 1991), there may
be any number of Parameter Bytes in the range 0x30 to 0x3F, and then
any number of Intermediate Bytes in the range 0x20 to 0x2F, between
the CSI and the Final Byte.
This version still does not support control sequences longer than
ITRM_IN_QUEUE_SIZE bytes.
To reproduce:
- Start ELinks.
- Enable the ui.tabs.wraparound option.
- Press t to open a second tab.
- Go to http://elinks.cz/ in the second tab.
- Press 3< to step three tabs to the left.
In the statement "tab = tabs + tab % tabs;", tab == -2 and tabs == 2.
So tab % tabs == 0 and tab becomes 2, which is out of range.
The new version calls get_opt_bool even if the tab parameter is already in
range, but the cost should be negligible compared to the redraw_terminal()
call that follows.
The configure script no longer recognizes "CONFIG_UTF_8=yes" lines
in custom features.conf files. They will have to be changed to
"CONFIG_UTF8=yes". This incompatibility was deemed acceptable
because no released version of ELinks supports CONFIG_UTF_8.
The --enable-utf-8 option was not renamed.
Suggested by Miciah on #elinks.
What was renamed:
add_utf_8 => add_utf8
cp2utf_8 => cp2utf8
encode_utf_8 => encode_utf8
get_translation_table_to_utf_8 => get_translation_table_to_utf8
goto invalid_utf_8_start_byte => goto invalid_utf8_start_byte
goto utf_8 => goto utf8
goto utf_8_select => goto utf8_select
terminal_interlink.utf_8 => terminal_interlink.utf8
utf_8_to_unicode => utf8_to_unicode
What was not renamed:
terminal._template_.utf_8_io option, TERM_OPT_UTF_8_IO
Compatibility with existing elinks.conf files would require an alias.
--enable-utf-8
Because the name of the charset is UTF-8, --enable-utf-8 looks better
than --enable-utf8.
CONFIG_UTF_8
Will be renamed in a later commit.
Unicode/utf_8.cp, table_utf_8, aliases_utf_8
Will be renamed in a later commit.
Reported by Jonas Fonseca.
Also add an empty line above the label in init_tab; but there are
still several labels elsewhere that don't have empty lines above them.
The previous scheme incorrectly accepted 0xC1 0x80 as U+0040.
That could have been fixed by tweaking the loop, but the constant
array is surely easier to verify.
In the previous version, invalid UTF-8 from a terminal caused
UCS_NO_CHAR (0xFFFFFFFD) to be stored in a term_event_key_T, resulting
in -3 which was then incidentally treated as an unassigned special key.
Now, invalid UTF-8 is instead mapped to UCS_REPLACEMENT_CHARACTER
and treated as a character. The fact that handle_interlink_event
calls term_send_ucs when it receives invalid UTF-8 makes it pretty
clear that this is how it was intended.
src/viewer/text/link.c (not changed in this commit) already referred
to UCS_REPLACEMENT_CHARACTER in a comment even though it was not
previously defined.
Decrement term->current_tab before calling delete_window() instead of after
deleting all backgrounded tabs, so get_tab_by_number() will see a
consistent value.